I was doing some reading in AITC 119 Standard Specifications for Structural Glued Laminated Timbers of Hardwood Species, Section 4.1.6 … “ … modulus of elasticity, E, values herein are the average values … The modulus of elasticity of wood …

AITC 119 and EEEE Read more »

The nice thing about a stiff beam is that it won’t sag much. The not-so-nice thing is that it won’t `give’. In new construction, wood framing more or less starts from the ground up; wood members are placed on top …

Jamming Jack Studs Read more »

Let’s look at a post, say in a shop, or a barn, acting as a vertical cantilever. This means that the base of the post is held rigid (not allowed to rotate), while a lateral (horizontal, or sideways) load is …

Cantilever Post Deflection (Post and Bracket) Read more »

Shear Deflection – Prefab Wood I-Joist Example Calc (c) Jeff R. Filler, Pell City, 2022 Continuing our discussion on shear deflection of wood beams (joists, etc.), let’s look at a prefabricated wood I-joists. Basic design information for prefabricated wood I-joists …

Shear Deflection – Prefab Wood I-Joist Read more »