Shear Deflection – Prefab Wood I-Joist Example Calc (c) Jeff R. Filler, Pell City, 2022 Continuing our discussion on shear deflection of wood beams (joists, etc.), let’s look at a prefabricated wood I-joists. Basic design information for prefabricated wood I-joists …

Shear Deflection – Prefab Wood I-Joist Read more »

E min (c) Jeff R. Filler, Pell City, Alabama, 2022 But First, E apparent and E true `E min’ is calculated wood property used in the design of structural wood members (beams, columns, etc.). It is a derived property, derived …

E min Read more »

In the example above (link) we calculated a deflection of 0.599 in. How accurate is this number? (I showed it to three significant figures … accurate to half a percent?) Leaving out, for now, the accuracy/precision of the other input, …

Accuracy of Deflection Calcs (and Eee) Read more »

E app (`Eee app’, `Eee apparent’, Apparent Modulus of Elasticity) is a design property for wood construction. It comes from the Modulus of Elasticity of the wood (E, MOE, Young’s Modulus). It’s not a `true’, or `pure’ property, and it …

E app (Apparent Modulus of Elasticity) Read more »